A fast algorithm for voxel-based deterministic simulation of X-ray imaging
Description
Abstract Deterministic method based on ray tracing technique is known as a powerful alternative to the Monte Carlo approach for virtual X-ray imaging. The algorithm speed is a critical issue in the perspective of simulating hundreds of images, notably to simulate tomographic acquisition or even more, to simulate X-ray radiographic video recordings. We present an algorithm for voxel-based deterministic simulation of X-ray imaging using voxel-driven forward and backward perspective projection operations... Title of program: X-ray Catalogue Id: AEAD_v1_0 Nature of problem Radiographic simulation of voxelized objects based on ray tracing technique. Versions of this program held in the CPC repository in Mendeley Data AEAD_v1_0; X-ray; 10.1016/j.cpc.2007.11.008 This program has been imported from the CPC Program Library held at Queen's University Belfast (1969-2019)